Architecture
Economic and administrative sciences
Sciences and Humanities
Engineering

Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.11839/6418
Title: Evaluación energética de escenarios de operación a partir de diagramas de Sankey para la planta de deshidratación de crudo en la estación Jaguar del Bloque Caracara
Authors: Díaz Pinzón, Daniel Felipe
Thesis advisor: Rodríguez Corrales, Juan Manuel
Secco López, Lina María
Villa Orrego, Luis Guillermo
License type: Atribución – No comercial
Keywords: Diagrama Sankey;Consumo energético;Planta deshidratación crudo;Estación Jaguar;Sankey diagrams;Energy consumption;Crude dehydration plant;Jaguar Station;Tesis y disertaciones académicas
Issue Date: 10-Aug-2017
Publisher: Fundación Universidad de América
Resumen: El presente trabajo estudia mediante la simulación de diagramas de Sankey en cinco escenarios de operación energética, en comparación al escenario de operación energético actual de la planta de deshidratación de crudo en la estación Jaguar, perteneciente al bloque Caracara y operada por la compañía Cepsa Colombia S.A. Durante la primera fase del proyecto se realizó una descripción acerca de las generalidades de la estación Jaguar, entre las cuales se encuentran, la historia del bloque Caracara, la localización geográfica, historia de producción y facilidades de producción y el funcionamiento de la estación. En la segunda fase se llevó a cabo la descripción del marco energético actual de la estación Jaguar, mediante los diagramas de Sankey e indicadores termoenergéticos que permiten evaluar cuantitativamente la operación actual. Luego se realizó la interpretación de las corrientes energéticas por medio de los diagramas de Sankey para cada uno de los escenarios de operación energética planteados, cuantificando los indicadores termoenergéticos del proceso y posteriormente poder evaluar cada uno de estos escenarios.
Abstract: The present work is based on the simulation of Sankey diagrams in five scenarios of energy operation, compared to the scenario of current energy operation of the crude dehydration plant at the Jaguar station, belonging to the Caracara block and operated by the company Cepsa Colombia S.A. During the first phase of the project, a description was given of the generalities of the Jaguar station, including the history of the Caracara block, geographic location, production history and production facilities and the operation of the station. In the second phase the description of the current energy framework of the Jaguar station was carried out, using Sankey diagrams and thermoenergetic indicators that allow quantitative evaluation of the current operation. Then the energy currents were interpreted through the Sankey diagrams for each of the energy operation scenarios, quantifying the thermoenergetic indicators of the process and then being able to evaluate each one of these scenarios.
URI: http://hdl.handle.net/20.500.11839/6418
Citation: APA 6th - Díaz Pinzón, D. F. (2017) Evaluación energética de escenarios de operación a partir de diagramas de Sankey para la planta de deshidratación de crudo en la estación Jaguar del Bloque Caracara (Trabajo de grado). Fundación Universidad de América. Retrieved from http://hdl.handle.net/20.500.11839/6418
Appears in Collections:Trabajos de grado - Ingeniería de Petróleos

Files in This Item:
File Description SizeFormat 
5121340-2017-2-IP.pdf7.49 MBAdobe PDFView/Open


This item is licensed under a Creative Commons Licence Creative Commons