Architecture
Economic and administrative sciences
- Economy
- Business Administration
- Statistics and Actuarial Sciences
- International Business
- Project Management Specialization
- Business Management Specialization
- ???jsp.home.menu-lumieres.ehuman???
- Occupational Health and Safety Management Specialization
- International Business and Economic Integration Specialization
- Master MBA Administration
- Master Degree in Human Talent Management
Sciences and Humanities
Engineering
- Industrial engineering
- Mechanical Engineering
- Petroleum engineering
- Chemical engineering
- Environmental engineering
- Energy Engineering
- Mechatronics Engineering
- Quality Management Specialization
- Environmental Management Specialization
- Master in Environmental Management for Competitiveness
- Master Degree in Comprehensive Quality and Productivity Management
- Reservoir Engineering Master
- Master in Advanced Hydrocarbon Recovery
Please use this identifier to cite or link to this item:
https://hdl.handle.net/20.500.11839/6847
Title: | Propuesta de mejora para el sistema de tratamiento de agua potable del acueducto Veredal Coovesur Ltda. E.S.P. del municipio de Fusagasugá-Cundinamarca |
Other Titles: | Proposal of improvement for the drinking water treatment system of the veredal Aqueduct Coovesur Ltda. E.S.P. of the municipality of Fusagasuga-Cundinamarca |
Authors: | Caicedo Cárdenas, Heidi Lorena Suárez Cruz, Erica Marcela |
Thesis advisor: | López, Alexander |
License type: | Atribución – No comercial |
Keywords: | Agua potable;Potabilización;Tratamiento de agua;Drinking water;Potabilization;Water treatment;Improvement;Tesis y disertaciones académicas |
Issue Date: | 9-Aug-2018 |
Publisher: | Fundación Universidad de América |
Resumen: | La planta de tratamiento de agua potable Coovesur del Municipio de Fusagasugá-Cundinamarca, potabiliza un promedio de 15 L/s de agua proveniente del río Batán. Posee una bocatoma, un desarenador, dos vertederos, dos tanques de mezcla rápida, en donde se aplica sulfato de aluminio Tipo A, dos sedimentadores, tres equipos de filtración, desinfección utilizando cloro gaseoso, tres tanques de almacenamiento, y un laboratorio con 3 equipos de medición. Para cada etapa se realizó un diagnóstico detallado de cada una de las operaciones unitarias para determinar la problemática en cada una de ellas. Se tomaron los análisis físicos – químicos y microbiológicos de agua cruda y potable, determinando los parámetros que incumplían o se encontraban por fuera de la resolución 2115 de 2007 (como color, aluminio, microbiológicos, cloro residual, hierro total y pH), estableciendo las que presentan dificultades. El problema crítico es la concentración promedio de aluminio 0,39 mg Al/L que históricamente sobrepasa el límite permitido para agua potable (0,2 mg Al/L), por esto se llevaron a cabo diferentes pruebas de jarras en donde se establecieron las dosificaciones del coagulante, el neutralizante, el desinfectante y la validación de un floculante. |
Abstract: | The Coovesur potable water treatment plant of the Municipality of Fusagasugá-Cundinamarca, makes an average of 15 L / s of water from the Batán River drinkable. It has one intake, one sand trap, two landfills, two quick mix tanks, where Type A aluminum sulphate is applied, two settlers, three filtration equipment, disinfection using chlorine gas, three storage tanks, and a laboratory with 3 equipment. measurement. For each stage, a detailed diagnostic was made of each of the unit operations to determine the problem in each one of them. The physical - chemical and microbiological analyzes of raw and drinking water were taken, determining the parameters that did not comply or were outside resolution 2115 of 2007 (such as color, aluminum, microbiological, residual chlorine, total iron and pH), establishing the that present difficulties. The critical problem is the average concentration of aluminum 0.39 mg Al / L that historically exceeds the permitted limit for drinking water (0.2 mg Al / L), for this reason different jar tests were carried out where the dosages of the coagulant, the neutralizer, the disinfectant and the validation of a flocculant. |
URI: | http://hdl.handle.net/20.500.11839/6847 |
Citation: | APA 6th - Caicedo Cárdenas, H. L. y Suárez Cruz, E. M. (2018) Propuesta de mejora para el sistema de tratamiento de agua potable del acueducto Veredal Coovesur Ltda. E.S.P. del municipio de Fusagasugá-Cundinamarca (Trabajo de grado). Fundación Universidad de América. Retrieved from http://hdl.handle.net/20.500.11839/6847 |
Appears in Collections: | Trabajos de grado - Ingeniería Química |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
6132201-2018-2-IQ.pdf | 5.45 MB | Adobe PDF | View/Open |