Architecture
Economic and administrative sciences
Sciences and Humanities
Engineering

Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.11839/6901
Title: Evaluación del comportamiento de agentes biocidas en la eliminación de microorganismos en un tanque de almacenamiento de diésel
Other Titles: Evaluation of the behavior of biocidal agents in the elimination of microorganisms in a diesel fuel storage tank
Authors: Correa Espinosa, María Alejandra
Thesis advisor: Mateus Sendoya, Juan Pablo
License type: Atribución – No comercial
Keywords: Biocida;Combustible diésel;Microorganismos;Biocide;Diesel fuel;Microorganisms;Tesis y disertaciones académicas
Issue Date: 13-Aug-2018
Publisher: Fundación Universidad de América
Resumen: El combustible diésel en Colombia, ha tenido cambios en los últimos años, debido a que se busca un producto cada vez más amigable con el medio ambiente. Éstos cambios han hecho que sea más susceptible al ataque microbiológico, lo cual genera la degradación de las propiedades del combustible, además de la aparición de sólidos en suspensión, lodos y borras. Finalmente, esto se traduce en mayores costos de operación para las estaciones de servicio (EDS) por drenajes de tanque y cambios de filtros, además de estar en riesgo de afectar los motores o sistemas de inyección del cliente final y adquirir sanciones por parte de la Superintendencia de Industria y Comercio. Al hacer un diagnóstico en 48 EDS a nivel nacional, se encontró que solamente el 33% de las muestras evaluadas tienen una buena apariencia, el 78% no aprueba el parámetro establecido de contenido de agua y sedimentos y el 90% de las EDS tienen contaminación microbiológica. Adicionalmente, se pudo evidenciar que hay una relación directa entre el contenido de agua y sedimentos de la muestra y la presencia de microorganismos.
Abstract: Diesel fuel in Colombia has undergone changes in recent years, due to the fact that it is looking for a product that is increasingly friendly to the environment. These changes have made it more susceptible to microbiological attack, which leads to the degradation of fuel properties, as well as the appearance of suspended solids, sludge and sludge. Finally, this translates into higher operating costs for service stations (EDS) due to tank drains and filter changes, as well as being at risk of affecting the engines or injection systems of the final customer and acquiring sanctions by the customer. Superintendence of Industry and Commerce. When making a diagnosis in 48 EDS at a national level, it was found that only 33% of the samples evaluated have a good appearance, 78% do not approve the established parameter of water and sediment content and 90% of the EDS have contamination microbiological Additionally, it was possible to demonstrate that there is a direct relationship between the water and sediment content of the sample and the presence of microorganisms.
URI: http://hdl.handle.net/20.500.11839/6901
Citation: APA 6th - Correa Espinosa, M. A. (2018) Evaluación del comportamiento de agentes biocidas en la eliminación de microorganismos en un tanque de almacenamiento de diésel (Trabajo de grado). Fundación Universidad de América. Retrieved from http://hdl.handle.net/20.500.11839/6901
Appears in Collections:Trabajos de grado - Ingeniería Química

Files in This Item:
File Description SizeFormat 
6131020-2018-2-IQ.pdf2.28 MBAdobe PDFView/Open


This item is licensed under a Creative Commons Licence Creative Commons