Título: Optimización de la capacidad volumétrica del actual sistema de vertimiento en campo Rubiales incrementándola a trescientos mil barriles de agua por día.
Otros títulos: Optimization of the volumetric capacity of the current production wastewater discharge system in the Rubiales field, increasing it to three hundred thousand barrels of water per day.
Autor(es): Arévalo Vargas, Jairo Eduardo
Gaitán Rojas, Juan José
Director de tesis: Agudelo Rincón, Héctor Jaime
Tipo de licencia: Atribución – No comercial
Palabras clave: Limpieza mecánica de tuberías;Pérdidas de presión;Sistema de vertimiento;Mechanical pipe cleaning;Pressure losses;Shedding system;Tesis y disertaciones académicas
Fecha de publicación: 27-jul-2021
Editorial: Fundación Universidad de América
Resumen: La pérdida de capacidad volumétrica en el sistema de vertimiento representa el desaprovechamiento en la capacidad de tratamiento de fluido lo cual se traduce en pérdida de producción. En este proyecto se realizó un análisis hidráulico, a partir de la información de diseño y operativa del sistema de vertimiento de Campo Rubiales, mediante la construcción de 3 distintos casos de simulación (Caso Ideal, Caso Representación Prueba de Bombas y Caso Actual). A partir de la comparación de las propiedades de diseño como el factor “C” entre los casos, los perfiles de presión obtenidos y la comparación de presión y caudal en el cabezal de distribución hacia los ramales de vertimiento C, D y E, se obtuvo como resultado que la diferencia de lecturas de presión en este punto entre el Caso Representación Prueba de Bombas y los verdaderos datos de la prueba era de 28 Psig en un sistema con un factor “C” común para tuberías en buen estado.
Abstract: The loss of volumetric capacity in the dumping system represents the waste of fluid treatment capacity, which translates into loss of production. In this project, a hydraulic analysis was carried out, based on the design and operational information of the Campo Rubiales dumping system, through the construction of 3 different simulation cases (Ideal Case, Pump Test Representation Case and Current Case). From the comparison of the design properties such as the factor “C” between the cases, the pressure profiles obtained and the comparison of pressure and flow in the distribution head towards the discharge branches C, D and E, it was obtained As a result, the difference in pressure readings at this point between the Pump Test Representation Case and the actual test data was 28 Psig in a system with a common “C” factor for pipes in good condition.
URI: https://hdl.handle.net/20.500.11839/8622
Citación: APA 7th - Arévalo Vargas, J. E. y Gaitán Rojas, J. J. (2021) Optimización de la capacidad volumétrica del actual sistema de vertimiento en campo Rubiales incrementándola a trescientos mil barriles de agua por día. [Trabajo de grado, Fundación Universidad de América] Repositorio Institucional Lumieres. https://hdl.handle.net/20.500.11839/8622
Aparece en las colecciones:Trabajos de grado - Ingeniería de Petróleos

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
5161461-2021-2-IP.pdf4.51 MBAdobe PDFVisualizar/Abrir
CARTA DE CESIÓN DE DERECHOS Y AUTORIZACIÓN PARA PUBLICACIÓN.pdf
Accesso Restringido
89.11 kBAdobe PDFVisualizar/Abrir    Request a copy


Este ítem está sujeto a una licencia Creative Commons Creative Commons