Title: Diseño técnico de una planta de tratamiento de aguas residuales (PTAR) procedentes de un centro de eventos ubicado a las afueras de Bogotá D.C.
Other Titles: Technical design of a wastewater treatment plant (WWTP) from an events center located on the outskirts of Bogotá D.C.
Authors: Talero Rodríguez, Francisco Javier
metadata.dc.contributor.advisordocentenoinv: Garzón Velasco, Diana Carolina
License type: Atribución – No comercial
Keywords: Aguas domésticas;Tratamiento biológico;Tratamiento de aguas;Domestic water;Biological treatment;Water treatment;Tesis y disertaciones académicas
Issue Date: 24-Aug-2023
Publisher: Fundación Universidad de América
Resumen: Este proceso de investigación presenta la incorporación de un diseño y modelamiento de una planta de tratamiento de aguas residuales provenientes de un centro de eventos ubicado a las afueras de Bogotá D.C. En términos generales se realizó un diagnóstico de la calidad del agua de salida, superando los límites permisibles en demanda química de oxígeno (DQO) y sólidos suspendidos totales (SST), tomando en consideración lo establecido en la resolución 0631 de 2015 para vertimientos en cuerpos hídricos. Partiendo de esta premisa, se generó el diseño, el cual parte de un pretratamiento mediante un sistema de rejas, un tratamiento primario que se basa en un mecanismo de sedimentación, pasando a un mecanismo secundario a partir de un sistema de lodos activados y llegando finalmente a la eliminación de componentes patógenos mediante cloración. Lo mencionado anteriormente ayudó a proporcionar una reducción del 48% y 56% con respecto al DQO y SST, respectivamente, posterior a la simulación del proceso mediante el uso del software especializado STOAT.
Abstract: This research process presents the incorporation of a design and modeling of a wastewater treatment plant from an events center located on the outskirts of Bogotá D.C. In general terms, a diagnosis of the quality of the outlet water was carried out, exceeding the permissible limits in chemical oxygen demand (COD) and total suspended solids (TSS), taking into consideration the provisions of resolution 0631 of 2015 for discharges into bodies. water. Starting from this premise, the design was generated, which starts from a pretreatment using a grid system, a primary treatment that is based on a sedimentation mechanism, moving on to a secondary mechanism based on an activated sludge system and finally arriving to the elimination of pathogenic components through chlorination. The aforementioned helped provide a reduction of 48% and 56% with respect to COD and TSS, respectively, after simulating the process through the use of the specialized STOAT software.
URI: https://hdl.handle.net/20.500.11839/9328
Citation: APA 7th - Talero Rodríguez, F. J. (2023) Diseño técnico de una planta de tratamiento de aguas residuales (PTAR) procedentes de un centro de eventos ubicado a las afueras de Bogotá D.C. [Trabajo de grado, Fundación Universidad de América] Repositorio Institucional Lumieres. https://hdl.handle.net/20.500.11839/9328
metadata.dc.publisher.program: Tratamiento de aguas residuales
Appears in Collections:Trabajos de grado - Gestión Ambiental

Files in This Item:
File Description SizeFormat 
32165-2023-2-GA.pdf346.04 kBAdobe PDFView/Open
CARTA DE CESIÓN DE DERECHOS Y AUTORIZACIÓN PARA PUBLICACIÓN.pdf
Access Restricted
1.84 MBAdobe PDFView/Open    Request a copy


This item is licensed under a Creative Commons Licence Creative Commons