Architecture
Economic and administrative sciences
- Economy
- Business Administration
- Statistics and Actuarial Sciences
- International Business
- Project Management Specialization
- Business Management Specialization
- ???jsp.home.menu-lumieres.ehuman???
- Occupational Health and Safety Management Specialization
- International Business and Economic Integration Specialization
- Master MBA Administration
- Master Degree in Human Talent Management
Sciences and Humanities
Engineering
- Industrial engineering
- Mechanical Engineering
- Petroleum engineering
- Chemical engineering
- Environmental engineering
- Energy Engineering
- Mechatronics Engineering
- Quality Management Specialization
- Environmental Management Specialization
- Master in Environmental Management for Competitiveness
- Master Degree in Comprehensive Quality and Productivity Management
- Reservoir Engineering Master
- Master in Advanced Hydrocarbon Recovery
Please use this identifier to cite or link to this item:
https://hdl.handle.net/20.500.11839/7815
Title: | Desarrollo de una metodología de monitoreo y control de la calidad de agua en la inyección de geles de dispersión coloidal en un campo ubicado en la cuenca del Valle superior del Magdalena |
Other Titles: | Development of a methodology for water quality surveillance and control in the injection of colloidal dispersion gels in a field located in the Upper Magdalena Basin |
Authors: | Castillo Vargas, Ivan Camilo Mendoza Arias, Laura Carlota |
Thesis advisor: | Ceballos Guerra, Rubén Darío |
License type: | Atribución – No comercial |
Keywords: | Agua de producción;Gel de dispersion coloidal;Calidad de agua;Monitoreo de agua;Produced water;Coloidal dispersion gel;Water quality;Water surveillance;Tesis y disertaciones académicas |
Issue Date: | 8-Feb-2020 |
Publisher: | Fundación Universidad de América |
Resumen: | En el desarrollo de la metodología de monitoreo y control de la calidad del agua de producción empleada en la inyección de geles de dispersión coloidal (CDG), se analizaron las caracterizaciones históricas del agua de producción del Campo A desde el año 2009 hasta la actualidad por medio del programa desarrollado titulado “Intelligent Water Management for CEOR Operations”. Con este programa se logró obtener las tendencias, los valores máximos y mínimos en los parámetros de salinidad, hierro, pH, dureza, oxígeno disuelto, entre otros, junto con el análisis hidrogeoquímico del agua, diagnosticando el estado actual del agua de producción y los porcentajes de reducción de las propiedades en el tratamiento aplicado en la Planta de Inyección (PIA). Por medio de un benchmarking de los procesos de monitoreo y control realizados por ECOPETROL, YPF y CNPC se seleccionaron las frecuencias de medición para los parámetros del agua y los puntos de control. Mediante el desarrollo experimental se evaluaron los límites máximos de los parámetros mencionados del agua de producción, tomando como variable de respuesta el porcentaje de reducción de la viscosidad de la solución de CDG; siendo el catión magnesio el que mayor porcentaje de reducción presentó y se establecieron los siguientes límites operacionales:1480 ppm de dureza total, 1020 ppm de dureza cálcica, 36 ppm para sulfatos, 990 ppm para carbonatos, 54 ppm para Bario, 9800 ppm de cloruros, 500 ppm para calcio, 100 ppm de magnesio, 32 ppm para estroncio, 110 ppm de potasio, pH menor a 8, oxígeno disuelto 32 ppb y 225 ppb en contenido de hierro. De esta forma, se establece la metodología de monitoreo y control para lograr la formación de la solución e CDG en el Campo A. |
Abstract: | In this work, a detailed analysis of the historical data from production water of Field A since 2009 was performed, using the software created "Intelligent Water Management for CEOR Operations". It was possible to obtain trends, max and minimum values in parameters of high importance for CEOR, such as Salinity, Dissolved iron, pH, Hardness, dissolved oxygen, among others using this software. The status of the operation of the water facility was diagnosed using hidrogeochemical analysis in order to determine the reduction of these parameters in the process. Comparing Ecopetrol with other companies, such as YPF and CNPC, was possible with a detailed benchmarking; which include best practices and innovative technology for the surveillance and control of these types of projects. Laboratory tests was pivotal in order to determine the max allowed values for the properties mentioned before, and the response variable in all of the experiments was the percentage of reduction of viscosity in the polymeric solution. The results allow concluding that the cation that affects more the viscosity is the Magnesium, establishing the following limits: Hardness 1480 ppm, Calcium Hardness 1020 ppm, Sulfates 36 ppm, Carbonates 990 ppm. Barium 54 ppm, Chloride 9800 ppm, Calcium 500 ppm, Magnesium 100 ppm, Strontium 32 ppm. Potassium 110 ppm, pH lower than 8, dissolved oxygen 32 ppb and dissolved iron 225 ppb. |
URI: | https://hdl.handle.net/20.500.11839/7815 |
Citation: | APA 6th - Castillo Vargas, I. C. y Mendoza Arias, L. C. (2020) Desarrollo de una metodología de monitoreo y control de la calidad de agua en la inyección de geles de dispersión coloidal en un campo ubicado en la cuenca del Valle superior del Magdalena (Trabajo de grado). Fundación Universidad de América. Retrieved from https://hdl.handle.net/20.500.11839/7815 |
Appears in Collections: | Trabajos de grado - Ingeniería de Petróleos Trabajos de grado - Ingeniería Química |