Arquitectura
Economía
Ciencias y humanidades
Ingenierías

Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/20.500.11839/7815
Título: Desarrollo de una metodología de monitoreo y control de la calidad de agua en la inyección de geles de dispersión coloidal en un campo ubicado en la cuenca del Valle superior del Magdalena
Otros títulos: Development of a methodology for water quality surveillance and control in the injection of colloidal dispersion gels in a field located in the Upper Magdalena Basin
Autor(es): Castillo Vargas, Ivan Camilo
Mendoza Arias, Laura Carlota
Director de tesis: Ceballos Guerra, Rubén Darío
Tipo de licencia: Atribución – No comercial
Palabras clave: Agua de producción;Gel de dispersion coloidal;Calidad de agua;Monitoreo de agua;Produced water;Coloidal dispersion gel;Water quality;Water surveillance;Tesis y disertaciones académicas
Fecha de publicación: 8-feb-2020
Editorial: Fundación Universidad de América
Resumen: En el desarrollo de la metodología de monitoreo y control de la calidad del agua de producción empleada en la inyección de geles de dispersión coloidal (CDG), se analizaron las caracterizaciones históricas del agua de producción del Campo A desde el año 2009 hasta la actualidad por medio del programa desarrollado titulado “Intelligent Water Management for CEOR Operations”. Con este programa se logró obtener las tendencias, los valores máximos y mínimos en los parámetros de salinidad, hierro, pH, dureza, oxígeno disuelto, entre otros, junto con el análisis hidrogeoquímico del agua, diagnosticando el estado actual del agua de producción y los porcentajes de reducción de las propiedades en el tratamiento aplicado en la Planta de Inyección (PIA). Por medio de un benchmarking de los procesos de monitoreo y control realizados por ECOPETROL, YPF y CNPC se seleccionaron las frecuencias de medición para los parámetros del agua y los puntos de control. Mediante el desarrollo experimental se evaluaron los límites máximos de los parámetros mencionados del agua de producción, tomando como variable de respuesta el porcentaje de reducción de la viscosidad de la solución de CDG; siendo el catión magnesio el que mayor porcentaje de reducción presentó y se establecieron los siguientes límites operacionales:1480 ppm de dureza total, 1020 ppm de dureza cálcica, 36 ppm para sulfatos, 990 ppm para carbonatos, 54 ppm para Bario, 9800 ppm de cloruros, 500 ppm para calcio, 100 ppm de magnesio, 32 ppm para estroncio, 110 ppm de potasio, pH menor a 8, oxígeno disuelto 32 ppb y 225 ppb en contenido de hierro. De esta forma, se establece la metodología de monitoreo y control para lograr la formación de la solución e CDG en el Campo A.
Abstract: In this work, a detailed analysis of the historical data from production water of Field A since 2009 was performed, using the software created "Intelligent Water Management for CEOR Operations". It was possible to obtain trends, max and minimum values in parameters of high importance for CEOR, such as Salinity, Dissolved iron, pH, Hardness, dissolved oxygen, among others using this software. The status of the operation of the water facility was diagnosed using hidrogeochemical analysis in order to determine the reduction of these parameters in the process. Comparing Ecopetrol with other companies, such as YPF and CNPC, was possible with a detailed benchmarking; which include best practices and innovative technology for the surveillance and control of these types of projects. Laboratory tests was pivotal in order to determine the max allowed values for the properties mentioned before, and the response variable in all of the experiments was the percentage of reduction of viscosity in the polymeric solution. The results allow concluding that the cation that affects more the viscosity is the Magnesium, establishing the following limits: Hardness 1480 ppm, Calcium Hardness 1020 ppm, Sulfates 36 ppm, Carbonates 990 ppm. Barium 54 ppm, Chloride 9800 ppm, Calcium 500 ppm, Magnesium 100 ppm, Strontium 32 ppm. Potassium 110 ppm, pH lower than 8, dissolved oxygen 32 ppb and dissolved iron 225 ppb.
URI: https://hdl.handle.net/20.500.11839/7815
Citación: APA 6th - Castillo Vargas, I. C. y Mendoza Arias, L. C. (2020) Desarrollo de una metodología de monitoreo y control de la calidad de agua en la inyección de geles de dispersión coloidal en un campo ubicado en la cuenca del Valle superior del Magdalena (Trabajo de grado). Fundación Universidad de América. Retrieved from https://hdl.handle.net/20.500.11839/7815
Aparece en las colecciones:Trabajos de grado - Ingeniería de Petróleos
Trabajos de grado - Ingeniería Química

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
5152233-2020-I-IPIQ.pdf6.44 MBAdobe PDFVisualizar/Abrir
CARTA DE CESIÓN DE DERECHOS Y AUTORIZACIÓN DE PUBLICACIÓN.pdf
Accesso Restringido
336.4 kBAdobe PDFVisualizar/Abrir    Request a copy


Este ítem está sujeto a una licencia Creative Commons Creative Commons